Lixian Instrument Scientific Co., Ltd
  • Ventilation type aging test chamber HZ-2010
  • Ventilation type aging test chamber HZ-2010
Ventilation type aging test chamber HZ-2010
The ventilation aging test chamber is suitable for the characteristics of wires, leather, plastics, rubber, cloth, before and after heating. In order to maintain fresh air in the chamber when the wires are heated, a special ventilation volume adjustment is made.
  • Tel:13711888650
  • Product Details

Equipment Overview


The machine used to test the material characteristic for wire type, skin type, plastic, rubber, cloth, Equipped with a special ventilation regulator for maintain the fresh air inside when heating. This testing machine design with sophisticated air-displacement adjustment device and a digital voltage meter, current meter, watt-hours, the timer can be used to measure the air replacement rate. Horizontal circulatory air supply system and both sides of airflow regulator to ensure the internal temperature uniformity and stability.


Main feature:

The oven used to study the rubber that is heated under the rotary mode in a fixed period. Tested 1 day at 70 ℃, theoretically equivalent to 6 months exposed to the outside atmosphere. The oven is equipped with motor-driven rotary disk, hot-air circulation system that ensure uniform distribution of temperature. Reference to ASTM, JIS, GB and other testing specifications.


Corresponding standard:

Accord with ASTM D5423-9(R2005)(Ⅱ-Type oven)and ASTMD 5374-93(2005) UL-1581、GB、VDE、JIS、IEC


Applicable industries:

The aging tank used to test the material heat-resisting for polymer materials (plastics, plastic) and electrical insulation materials, such as: wire and cable sheathing, heat-shrinkable tubing, rubber or PVC materials.


Technical parameters:

 

Testing space

About 45×50×45cm

Temperature

RT~200℃resolution: 0.1℃accuracy: 0.5℃

Rotation

0~10 or 10~200 time/H

Ventilation adjusted

Auto-tuning type

Ventilation system

Using voltage regulator to change the volume of air, convenient to adjust

Built-in circulating air system

Ensure the temperature uniformly: 1%(count at the highest temperature)

Material

SUS#304 stainless steel

Protector

Over-temperature breaker

Control system

TCM control system can make the amount of increase heat is equal to heat of loss

With P.I.D automatic calculation function, precision temperature control

Sensor

high-accuracy PT100 thermocouple temperature fluctuation 0.5% (count at the highest temperature)

Inside size

50cm (L)x 40 cm(D)x 50 cm(H)

Outside size

120cm (L)x 65 cm (D)x 134 cm(H)

Insulation material

80mm rock wool

Count the volume of air

formula for Japan JIS72123590 N=

3590X-Y

V x D x △T


N: The number of air exchange in 1 hour

X: The consumption of electricity in ventilation WH

Y: The consumption of electricity in no ventilation WH    

V: Volume (cm3)

D: Density of air (g/cm3)

△T:Temperature contrast between inside and outside